Below are triggers and macros settings for airport doors when using Aero hardware and Symphony AC.
Drive Gate Settings:
Input Supervision for input 1: 0 normally closed Input Supervision for input 2: 1 normally open Note: If input 1 and/or input 2 are red, in the hardware properties, then check wiring Default reader mode: Card Only (for both readers) Door Held Time, Door Contact Input 2: 50 seconds Output 1 Pulse Time: 35 seconds Reader 1, Reader settings: 001-Paired (Master) Reader 2, Reader settings: 002-Paired (Slave)
Door Definitions:
Door Strike: 0: door has no impact on strike control For Reader 1, select Paired (Slave) Reader: the second reader For Reader 2, select Paired (Master) Reader: the first reader Door Contact Address: Input 2 REX1 Address: Input 3 REX2 Address: None
Crash Bar Door Type:
Door Strike Pulse Time = 5 seconds Door Held Open Time = 16 seconds Input #2 is a Monitor Point, no REX configuration
Baggage 30 Door Type:
Door Strike Pulse Time = 10 seconds Door Held Open Time = 1800 seconds (30 minutes) Door Strike Mode = No Impact Only cards with Trigger Code 1 will work
Baggage 60 Door Type:
Door Strike Pulse Time = 10 seconds Door Held Open Time = 3600 seconds (60 minutes) Door Strike Mode = No Impact Only cards with Trigger Code 1 will work Drive Gate Door Type: Door Strike Pulse Time = 45 seconds Door Held Open Time = 60 seconds Door Strike Mode = No Impact Only cards with Trigger Code 1 will work Input #2 is a Monitor Point, no REX configuration
Jetway Door Type:
Door Strike Pulse Time = 5 seconds Output #2 Pulse Time = 5 seconds Door Held Open Time = 1800 seconds (30 minutes) Door Strike Mode = No Impact Only cards with Trigger Code 1 will work Input #2 is a Monitor Point, no REX configuration