Bosch DX4020
DX4020 Connection - RPS
- Flip the dip switches 1,2,3 to the down position. The remaining dip switches should be in the up position.
- Power down the device.
- Reapply power to the device.
- From the command prompt type telnet xxx.xxx.xxx.xxx 9999 (where xxx.xxx.xxx.xxx is the IP address of the DX4020).
- Enter 1 for channel and press the Enter key. The following properties should be modified.
- Port = 7700
- Connection Mode = CC
- Datagram Type = 02
- Enter 9 to save the changes
- Install the RPS software and dongle drivers. The software version must be version 5.12 or greater in order to function with Symphony AC.
- User Name = admin
- Password = 1111
- From the primary screen click on New and select D9412GV3.
- Highlight the panel and click on View, Edit, Network.
- Type the IP address and click OK.
- Double mouse click on the panel and click on the Connection button.
- Select Network from the drop down pick list and click Connect.
- Connection should be established in a few seconds. With the panel connected, select GV2 AUX. Double mouse click on the SDI Automation and select Yes from the drop down pick list to enable SDI Automation.
- Click Save and OK.
- Click on Send and Receive.
- Select Send to Panel.
- Click Disconnect.
Setting the DX4020 Connection for Symphony AC
- Flip dip switch seven (7) to the up position, all remaining dip switches should be in the down position.
- Power down the device and reapply power after five (5) seconds.
- From the command prompt type telnet xxx.xxx.xxx.xxx 9999 (where xxx.xxx.xxx.xxx is the IP address of the DX4020).
- Enter 1 for chan3001
- Connection Mode = C0
- Accept the remaining defaults and enter nine (9) to Save and Exit.
NOTE: The firmware revision MUST be version 8.05 in order to function properly with Symphony AC and GV3 panels. Please contact Bosch for the firmware upgrade if necessary.